Our Reverberation Chamber is capable of generating very high RF Field Strengths, typically 200 V/m as required by the Automotive Standard. The Double door entry system and 15m³ Test Area allow for large EUTs or Wiring Looms to be laid out negating the need to move the loom for different tests.
Test Standards
Vehicle Directives 2004/104/EC and 95/54/EC
- CISPR 25 150 kHz-1 GHz E Field
- ISO 11451-1 : 3rd Ed 2003
- ISO 11451-2 : 2nd Ed 2004
- ISO 11451-4 : 1995
- ISO 11452-1 : 3rd Ed 2005
- ISO 11452-2 : 2nd Ed 2004
- 80 MHz-3 GHz 50 V/m 80% AM 1 kHz & Pulse
- 3 GHz-18 GHz 30 V/m 80% AM 1 kHz & Pulse
- ISO 11452-4 : 2nd Ed 2001
- ISO 111452-5 : 2nd Ed 2002
- ISO 10605 : 2001
- ISO 7637-1
- ISO 7637-2
- ISO 7637-3
- ISO 16750-2
GMW 3100 : Aug 2001 and SAE J1113/27
In addition to the above standards:
- Radiated Emissions 3.2.1.1 150 kHz - 18 GHz E Field
- Conducted Emissions 3.2.1.1.3 10 kHz - 400 MHz E Field
- Radiated Immunity 3.2.1.2 400 MHz - 10G Hz using Reverberation Chamber 10 kHz - 150 MHz 10 V/m 100 MHz - 1 GHz 200 V/m CW+AM 350 V/m Pulse 1GHz - 18 GHz 50 V/m CW+AM
- Conducted Immunity 10 kHz - 400 MHz 100 mA, 1 A 10 MHz - 30 MHz
- Immunity Power Line Magnetic Field 3.2.1.2.5 300 A/m